Quality assurance
- Chemical analysis determination by emission spectroscopy
- Conductively test
- Mechanical material test
- Leakage test (LT)
- Penetration test (PT)
- Ultrasonic test (UT)
- X-ray test (RT)
- Dimensions check
- Pressure drop test (FT) Endoscopy
NAME AND ABBREVIATIONS
ISO | UNI | BS | AFNOR | DIN | ASTM |
---|---|---|---|---|---|
Cu-CATH | Cu-CATH 5649/3-88 | Cu-CATH-2 | KE-Cu 2.0050 1708 | CATH B 115 - 83 | |
Cu-ETP | Cu-ETP 5649/1-88 | Cu-ETP C 101 6017:1981 | Cu-a1 51-50 1983 | E-Cu 57 2.0060 1787 E-Cu 58 2.0065 1787 |
ETP C 11000 |
Cu-FRHC | Cu-FRHC 5649/1-88 | Cu-FRHC C 102 6017:1981 | Cu-a2 51-50 1983 | FRHC C 11020 | |
Cu-OFE | Cu-OFE C 110 6017:1981 | Cu-c2 51-50 1983 | OFE C 10100 B 170 -82 | ||
Cu-OF 1337 - 1980 (E) | Cu-OF 5649/1-88 | Cu-OF C 103 6017:1981 | Cu-c1 51-50 1983 | OF-Cu 2.0040 1787 | OF C 10200 B 170 - 82 |
Cu-HCP 431 - 1981 | Cu-HCP 5649/1-88 | SE-Cu 2.0070 1787 | OFXLP C 10300 B 379 - 80 | ||
Cu-DLP 1337 - 1980 (E) | Cu-DLP 5649/1-88 | Cu-b2 51-50 1983 | SW-Cu 2.0076 1787 | DLP C 12000 | |
Cu-DHP 1337 - 1980 (E) | Cu-DHP 5649/1-88 | Cu-DHP C 106 6017:1981 | Cu-b1 51-50 1983 | SF-Cu 2.0090 1787 | DHP C 12200 B 379 - 80 |
Cu-Ag 0,05 5649/2-88 | Cu-Ag 0,05 | ||||
Cu-Ag 0,1 5649/2-88 | Cu-Ag 0,1 | Cu Ag 0,1 2.1203 17666 | |||
Cu-Ag 0,05 (OF) 1336-1980 (E) | Cu-Ag 0,05 (OF) 5649/2-88 | Cu-Ag 0,05 (OF) | |||
Cu-Ag 0,1 (OF) 1336-1980 (E) | Cu-Ag 0,1 (OF) 5649/2-88 | Cu-Ag 0,1 (OF) | |||
Cu-Ag 0,05 (OF) 1336-1980 (E) | Cu-Ag 0,05 (P) 5649/2-88 | Cu-Ag 0,05 (P) | |||
Cu-Ag 0,1 (OF) 1336-1980 (E) | Cu-Ag 0,1 (P) 5649/2-88 | Cu-Ag 0,1 (P) | Cu-Ag 0,1 P 2.1191 17666 | ||
Cu Cd 0,5 5649/2-88 | C 16200 | ||||
Cu Cd 1 5649/2-88 | C 108 | ||||
Cu As (P) 5649/2-88 | C 107 | DPA C 14200 B379 - 80 | |||
Cu S (P 0,01) 5649/2-88 | C 111 | Cu-S (P 0,01) | Cu S P 2.1498 17666 | ||
Cu S (P 0,03) 5649/2-88 | Cu-S (P 0,03) | C 14710 | |||
Cu Te (OF) 5649/2-88 | |||||
Cu Te (P) 5649/2-88 | C 109 | Cu-Te (P) | Cu Te P 2.1546 17666 | DPTE C 14500 |